Saeshin TRAUS Optic LED Implant System
Specification:
with LED
1. This products is designed for bone surgery (implant surgery). Please use the product in a proper use and method.
2. Please pay attention to the use considering the patient's safety first of all.
3. Please read the instruction manual thoroughly for understanding the functions and then use the product.
4. Check the working status before the surgery and use the product if there is no problem.
5. Stop working and check the problem if there is vibration, heating or strange sound before or during the use.
6. Ask to the manufacturer if the problem is abnormal or unsolved easily.
7. Please prepare the extra consumable parts before use. Especially, the contra angle handpiece doesn't work if the blood or a saline solution comes into the head. So that we recommend to have an extra for safety.
8. Make sure to put a plug in an outlet with earth.
9. Change or insert the bur after the motor stops completely. Otherwise, the inside of contra angle handpiece could be damaged by the bur and it will cause an accident.
10. Do not drop from on high or give shock on the product. It damages the product.
11. In case the irigation pump doesn't work, do not bend or fold the tube. The tube will be broken or taken off.
12. Do not disassemble or modify the product. When disassembled, the after service is not avilable.
13. Please sterilize and lubricate the hadnpiece immediately after use. Otherwise, the product could be damaged because of coagulation by the blood or remains from surgery.
14. Do not insert the oil into the motor. It damages the bearing or causes heating.
15. The control unit and foot control pedal are not autoclavable.
16. If the control unit is contaminated, clean with wet cloth and then remove the moisture with dry cloth after turning the power off.
17. Do not use the solvent such as sinner or benzene for cleaning.
18. The input power is available at AC100~120V / 220~240V.
** (Check input voltage before connecting the AC power)
19. Dispose the irigation tube after use as medical waste.
-it could be a main cause of the breakdown or infection.
-When using drill bit, follow the instruction for use provided by the drill manufucturer.
Using it over speed limit may cause an accident.
-If display is malfunctioning, contact to manufacturer or contact to the place purchaded.
It may cause an accident.
-Use the authenticated product and consumable parts by manufacturer.
Otherwise, it may cause a malfunction or an accident.